Message-ID: <9074454.1075842483888.JavaMail.evans@thyme> Date: Fri, 1 Dec 2000 00:08:00 -0800 (PST) From: keith.petersen@enron.com To: mary.miller@enron.com, drew.fossum@enron.com Subject: Gallup Mime-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Transfer-Encoding: 7bit X-From: Keith Petersen X-To: Mary Kay Miller, Drew Fossum X-cc: X-bcc: X-Folder: \Drew_Fossum_Dec2000_June2001_1\Notes Folders\Notes inbox X-Origin: FOSSUM-D X-FileName: dfossum.nsf The note below was a portion of Terry Galassini's Weekly Report. I wasn't sure if either of you have been a part of the test information. **Gallup Compressor Station & Mainline Expansion A field test was completed and initial results indicate a compressor efficiency around 80 - 82% which is within Cooper's guarantee. A not to exceed cost of $3 Million was provided to Marketing for station modifications to facilitate an incremental mainline (West of Thoreau) firm capacity of 10 MMcf/d. Additional work by E&C to fine tune the not to exceed estimate is targeted for completion by December 8th. The mainline expansion potential is directly related to Gallup since the discharge pressure must be increased to 970 psig to achieve an additional 10 MMcf/d on the mainline. The San Juan Lateral firm capacity would remain at 850 MMcf/d.